分类: 压力变送器
Performance Characteristics SPX5- Series | |
Output | 4 - 20 mA, with optional HART™ |
Input Voltage | 16 - 36 Vdc (Std); 16 - 30 Vdc (ATEX IS) |
Accuracy | All Models ± 0.20% |
Repeatability | ±0.1% |
Rangeability | 3:1 Turndown |
Over Pressure | 2X FSO or 35,000 psi,whichever is less (5390, 5391, & 5392 1.5 x FSO for 10,000 psi) |
Zero Balance Adjustment Range | (-)40% to +10%;(-)80% to 20% for FSP < 500 psi |
Load Resistance | 500 Ω @ 24 Vdc, 1,000 Ω @ 36 Vdc |
Electronics Ambient Temperature | 70°F (20°C) |
Electronics Operating Temperature | -20 to 185°F (-29 to 85°C) |
Diaphragm Temperature | 750°F (400°C) max [Models 5344, 5390, 5391, 5392 limited to 600°F (315°C)] |
Electronics Compenstated Temperature Range | 0 to 150°F (-18 to 65°C) |
Zero Shift (Electronics Temp Change) | All Models: 0.01% FS/°F max (0.02% FS/°C max) |
Span Shift (Electronics Temp Change | All Models: 0.01% FS/°F max (0.02% FS/°C max) |
Zero Shift (Snout Temp Change) | 5344/5390/5391/5392: 1 psi/100°F (from 75-450°F) typical 2 psi/100°F (from 450-600°F) typical 5342/5343: 15 psi/100°F (27 psi/100°C) typical |
Performance Characteristics SPX5- Series | |
Output | 4 - 20 mA, with optional HART™ |
Input Voltage | 16 - 36 Vdc (Std); 16 - 30 Vdc (ATEX IS) |
Accuracy | All Models ± 0.20% |
Repeatability | ±0.1% |
Rangeability | 3:1 Turndown |
Over Pressure | 2X FSO or 35,000 psi,whichever is less (5390, 5391, & 5392 1.5 x FSO for 10,000 psi) |
Zero Balance Adjustment Range | (-)40% to +10%;(-)80% to 20% for FSP < 500 psi |
Load Resistance | 500 Ω @ 24 Vdc, 1,000 Ω @ 36 Vdc |
Electronics Ambient Temperature | 70°F (20°C) |
Electronics Operating Temperature | -20 to 185°F (-29 to 85°C) |
Diaphragm Temperature | 750°F (400°C) max [Models 5344, 5390, 5391, 5392 limited to 600°F (315°C)] |
Electronics Compenstated Temperature Range | 0 to 150°F (-18 to 65°C) |
Zero Shift (Electronics Temp Change) | All Models: 0.01% FS/°F max (0.02% FS/°C max) |
Span Shift (Electronics Temp Change | All Models: 0.01% FS/°F max (0.02% FS/°C max) |
Zero Shift (Snout Temp Change) | 5344/5390/5391/5392: 1 psi/100°F (from 75-450°F) typical 2 psi/100°F (from 450-600°F) typical 5342/5343: 15 psi/100°F (27 psi/100°C) typical |